The Server Technology® PRO2 Switched POPS PDU provides control of outlet power and local LED input current monitoring, allowing IT personnel to determine safe levels of loading on a per-phase basis while installing equipment into the rack/cabinet. The integral PIPS® and POPS® technology provides billing-grade accurate measurement of current, voltage, active power, apparent power, power factor, crest factor, and accumulated energy at the input and at each output. These power data points, along with temperature and humidity measurements (provided via optional probes), are accessible through the built-in Web and CLI interfaces as well as through SNMP. The PRO2 Switched POPS "Primary" PDU can be connected to as many as three (with optional module) PRO2 Switched POPS "Link" PDUs to extend the network access to the redundant or secondary power feed without the risks of a daisy chain linking configuration.
- Color-Coded Options: Select from six colors to designate PDU circuits in the data center - black, white, red, green, blue, and yellow.
- High Retention Locking Outlets: PRO2 receptacles have high retention and are compatible with P-Lock type power cords.
- Outlet Control: On Switched rack PDUs, cycle power to individual outlets or groups of outlets to reboot servers. Or, power off unused receptacles.
- Branch Circuit Protection: This PDU meets the UL and IEC 60950-1 requirement for branch circuit protection through use of UL489 rated magnetic-hydraulic circuit breakers or UL248 fuses.
- Branch Current Monitoring: Monitors current at each breaker branch and provides SNMP-based alerts and emails on high usage that risks a tripped circuit.
- Per-Outlet Power Sensing: POPS® (Per Outlet Power Sensing) Monitors Current Load (A), Voltage (V), Power (W), Apparent Power (VA), Crest Factor, Power Factor, and Energy per outlet.
- Per-Inlet Power Sensing: Meets ANSI C12.1 for billing-grade accuracy of Current per phase. PIPS inc
| Brand | |
|---|---|
| Brand | Server Technology |
| Power & Battery | |
|---|---|
| Power Rating (Watt) | 8600 W |
| PDU Type | Switched |
| Remote Outlet Switching | Yes |
| Phase | Three Phase |
| Input Frequency | 60 Hz |
| Circuit Breaker | Yes |
| Receptacle Detail | 6 x CX |
| Receptacle Type | CX |
| Plug/Connector Type | NEMA L15-30P |
| Locking Receptacles | P-Lock |
| Input Voltage | 230 V AC |
| Output Voltage | 208 V AC |
| Input Current | 30 A |
| Load Capacity (Watt) | 8600 W |
| Ethernet Port | |
|---|---|
| Network (RJ-45) | Yes |
| Size / Dimensions | |
|---|---|
| Mount Type | Button Mount |
| General Features | |
|---|---|
| Protection Type | Fuse |
| Manufacturer | Legrand Group |
| Compliance & Certification | |
|---|---|
| Maximum Operating Temperature | 122°F (50°C) |
| Minimum Operating Temperature | 32°F (0°C) |
| Maximum Storage Temperature | 185°F (85°C) |
| Minimum Storage Temperature | -40°F (-40°C) |
| Maximum Operating Humidity | 90% |
| Minimum Operating Humidity | 8% |
| Brand | Server Technology, Inc |
| MPN | C2XG24SN-DCLN5D6 |
| Unit Count | 1 Units |
| Warranty | 2 Year |
| Return Policy | This product is eligible for 30-day returns subject to a restocking fee. See our return policy for details. |